Update nvdimm option value in example command from "-machine pc,nvdimm" to "-machine pc,nvdimm=on" as former complains with the below error: "qemu-system-x86_64: -machine pc,nvdimm: Expected '=' after parameter 'nvdimm'" Reviewed-by: Laurent Vivier <laurent@vivier.eu> Signed-off-by: Pankaj Gupta <pankaj.gupta.linux@gmail.com> Message-Id: <20210923103015.135262-1-pankaj.gupta.linux@gmail.com> Signed-off-by: Laurent Vivier <laurent@vivier.eu>
265 lines
10 KiB
Text
265 lines
10 KiB
Text
QEMU Virtual NVDIMM
|
|
===================
|
|
|
|
This document explains the usage of virtual NVDIMM (vNVDIMM) feature
|
|
which is available since QEMU v2.6.0.
|
|
|
|
The current QEMU only implements the persistent memory mode of vNVDIMM
|
|
device and not the block window mode.
|
|
|
|
Basic Usage
|
|
-----------
|
|
|
|
The storage of a vNVDIMM device in QEMU is provided by the memory
|
|
backend (i.e. memory-backend-file and memory-backend-ram). A simple
|
|
way to create a vNVDIMM device at startup time is done via the
|
|
following command line options:
|
|
|
|
-machine pc,nvdimm=on
|
|
-m $RAM_SIZE,slots=$N,maxmem=$MAX_SIZE
|
|
-object memory-backend-file,id=mem1,share=on,mem-path=$PATH,size=$NVDIMM_SIZE,readonly=off
|
|
-device nvdimm,id=nvdimm1,memdev=mem1,unarmed=off
|
|
|
|
Where,
|
|
|
|
- the "nvdimm" machine option enables vNVDIMM feature.
|
|
|
|
- "slots=$N" should be equal to or larger than the total amount of
|
|
normal RAM devices and vNVDIMM devices, e.g. $N should be >= 2 here.
|
|
|
|
- "maxmem=$MAX_SIZE" should be equal to or larger than the total size
|
|
of normal RAM devices and vNVDIMM devices, e.g. $MAX_SIZE should be
|
|
>= $RAM_SIZE + $NVDIMM_SIZE here.
|
|
|
|
- "object memory-backend-file,id=mem1,share=on,mem-path=$PATH,
|
|
size=$NVDIMM_SIZE,readonly=off" creates a backend storage of size
|
|
$NVDIMM_SIZE on a file $PATH. All accesses to the virtual NVDIMM device go
|
|
to the file $PATH.
|
|
|
|
"share=on/off" controls the visibility of guest writes. If
|
|
"share=on", then guest writes will be applied to the backend
|
|
file. If another guest uses the same backend file with option
|
|
"share=on", then above writes will be visible to it as well. If
|
|
"share=off", then guest writes won't be applied to the backend
|
|
file and thus will be invisible to other guests.
|
|
|
|
"readonly=on/off" controls whether the file $PATH is opened read-only or
|
|
read/write (default).
|
|
|
|
- "device nvdimm,id=nvdimm1,memdev=mem1,unarmed=off" creates a read/write
|
|
virtual NVDIMM device whose storage is provided by above memory backend
|
|
device.
|
|
|
|
"unarmed" controls the ACPI NFIT NVDIMM Region Mapping Structure "NVDIMM
|
|
State Flags" Bit 3 indicating that the device is "unarmed" and cannot accept
|
|
persistent writes. Linux guest drivers set the device to read-only when this
|
|
bit is present. Set unarmed to on when the memdev has readonly=on.
|
|
|
|
Multiple vNVDIMM devices can be created if multiple pairs of "-object"
|
|
and "-device" are provided.
|
|
|
|
For above command line options, if the guest OS has the proper NVDIMM
|
|
driver (e.g. "CONFIG_ACPI_NFIT=y" under Linux), it should be able to
|
|
detect a NVDIMM device which is in the persistent memory mode and whose
|
|
size is $NVDIMM_SIZE.
|
|
|
|
Note:
|
|
|
|
1. Prior to QEMU v2.8.0, if memory-backend-file is used and the actual
|
|
backend file size is not equal to the size given by "size" option,
|
|
QEMU will truncate the backend file by ftruncate(2), which will
|
|
corrupt the existing data in the backend file, especially for the
|
|
shrink case.
|
|
|
|
QEMU v2.8.0 and later check the backend file size and the "size"
|
|
option. If they do not match, QEMU will report errors and abort in
|
|
order to avoid the data corruption.
|
|
|
|
2. QEMU v2.6.0 only puts a basic alignment requirement on the "size"
|
|
option of memory-backend-file, e.g. 4KB alignment on x86. However,
|
|
QEMU v.2.7.0 puts an additional alignment requirement, which may
|
|
require a larger value than the basic one, e.g. 2MB on x86. This
|
|
change breaks the usage of memory-backend-file that only satisfies
|
|
the basic alignment.
|
|
|
|
QEMU v2.8.0 and later remove the additional alignment on non-s390x
|
|
architectures, so the broken memory-backend-file can work again.
|
|
|
|
Label
|
|
-----
|
|
|
|
QEMU v2.7.0 and later implement the label support for vNVDIMM devices.
|
|
To enable label on vNVDIMM devices, users can simply add
|
|
"label-size=$SZ" option to "-device nvdimm", e.g.
|
|
|
|
-device nvdimm,id=nvdimm1,memdev=mem1,label-size=128K
|
|
|
|
Note:
|
|
|
|
1. The minimal label size is 128KB.
|
|
|
|
2. QEMU v2.7.0 and later store labels at the end of backend storage.
|
|
If a memory backend file, which was previously used as the backend
|
|
of a vNVDIMM device without labels, is now used for a vNVDIMM
|
|
device with label, the data in the label area at the end of file
|
|
will be inaccessible to the guest. If any useful data (e.g. the
|
|
meta-data of the file system) was stored there, the latter usage
|
|
may result guest data corruption (e.g. breakage of guest file
|
|
system).
|
|
|
|
Hotplug
|
|
-------
|
|
|
|
QEMU v2.8.0 and later implement the hotplug support for vNVDIMM
|
|
devices. Similarly to the RAM hotplug, the vNVDIMM hotplug is
|
|
accomplished by two monitor commands "object_add" and "device_add".
|
|
|
|
For example, the following commands add another 4GB vNVDIMM device to
|
|
the guest:
|
|
|
|
(qemu) object_add memory-backend-file,id=mem2,share=on,mem-path=new_nvdimm.img,size=4G
|
|
(qemu) device_add nvdimm,id=nvdimm2,memdev=mem2
|
|
|
|
Note:
|
|
|
|
1. Each hotplugged vNVDIMM device consumes one memory slot. Users
|
|
should always ensure the memory option "-m ...,slots=N" specifies
|
|
enough number of slots, i.e.
|
|
N >= number of RAM devices +
|
|
number of statically plugged vNVDIMM devices +
|
|
number of hotplugged vNVDIMM devices
|
|
|
|
2. The similar is required for the memory option "-m ...,maxmem=M", i.e.
|
|
M >= size of RAM devices +
|
|
size of statically plugged vNVDIMM devices +
|
|
size of hotplugged vNVDIMM devices
|
|
|
|
Alignment
|
|
---------
|
|
|
|
QEMU uses mmap(2) to maps vNVDIMM backends and aligns the mapping
|
|
address to the page size (getpagesize(2)) by default. However, some
|
|
types of backends may require an alignment different than the page
|
|
size. In that case, QEMU v2.12.0 and later provide 'align' option to
|
|
memory-backend-file to allow users to specify the proper alignment.
|
|
For device dax (e.g., /dev/dax0.0), this alignment needs to match the
|
|
alignment requirement of the device dax. The NUM of 'align=NUM' option
|
|
must be larger than or equal to the 'align' of device dax.
|
|
We can use one of the following commands to show the 'align' of device dax.
|
|
|
|
ndctl list -X
|
|
daxctl list -R
|
|
|
|
In order to get the proper 'align' of device dax, you need to install
|
|
the library 'libdaxctl'.
|
|
|
|
For example, device dax require the 2 MB alignment, so we can use
|
|
following QEMU command line options to use it (/dev/dax0.0) as the
|
|
backend of vNVDIMM:
|
|
|
|
-object memory-backend-file,id=mem1,share=on,mem-path=/dev/dax0.0,size=4G,align=2M
|
|
-device nvdimm,id=nvdimm1,memdev=mem1
|
|
|
|
Guest Data Persistence
|
|
----------------------
|
|
|
|
Though QEMU supports multiple types of vNVDIMM backends on Linux,
|
|
the only backend that can guarantee the guest write persistence is:
|
|
|
|
A. DAX device (e.g., /dev/dax0.0, ) or
|
|
B. DAX file(mounted with dax option)
|
|
|
|
When using B (A file supporting direct mapping of persistent memory)
|
|
as a backend, write persistence is guaranteed if the host kernel has
|
|
support for the MAP_SYNC flag in the mmap system call (available
|
|
since Linux 4.15 and on certain distro kernels) and additionally
|
|
both 'pmem' and 'share' flags are set to 'on' on the backend.
|
|
|
|
If these conditions are not satisfied i.e. if either 'pmem' or 'share'
|
|
are not set, if the backend file does not support DAX or if MAP_SYNC
|
|
is not supported by the host kernel, write persistence is not
|
|
guaranteed after a system crash. For compatibility reasons, these
|
|
conditions are ignored if not satisfied. Currently, no way is
|
|
provided to test for them.
|
|
For more details, please reference mmap(2) man page:
|
|
http://man7.org/linux/man-pages/man2/mmap.2.html.
|
|
|
|
When using other types of backends, it's suggested to set 'unarmed'
|
|
option of '-device nvdimm' to 'on', which sets the unarmed flag of the
|
|
guest NVDIMM region mapping structure. This unarmed flag indicates
|
|
guest software that this vNVDIMM device contains a region that cannot
|
|
accept persistent writes. In result, for example, the guest Linux
|
|
NVDIMM driver, marks such vNVDIMM device as read-only.
|
|
|
|
Backend File Setup Example
|
|
--------------------------
|
|
|
|
Here are two examples showing how to setup these persistent backends on
|
|
linux using the tool ndctl [3].
|
|
|
|
A. DAX device
|
|
|
|
Use the following command to set up /dev/dax0.0 so that the entirety of
|
|
namespace0.0 can be exposed as an emulated NVDIMM to the guest:
|
|
|
|
ndctl create-namespace -f -e namespace0.0 -m devdax
|
|
|
|
The /dev/dax0.0 could be used directly in "mem-path" option.
|
|
|
|
B. DAX file
|
|
|
|
Individual files on a DAX host file system can be exposed as emulated
|
|
NVDIMMS. First an fsdax block device is created, partitioned, and then
|
|
mounted with the "dax" mount option:
|
|
|
|
ndctl create-namespace -f -e namespace0.0 -m fsdax
|
|
(partition /dev/pmem0 with name pmem0p1)
|
|
mount -o dax /dev/pmem0p1 /mnt
|
|
(create or copy a disk image file with qemu-img(1), cp(1), or dd(1)
|
|
in /mnt)
|
|
|
|
Then the new file in /mnt could be used in "mem-path" option.
|
|
|
|
NVDIMM Persistence
|
|
------------------
|
|
|
|
ACPI 6.2 Errata A added support for a new Platform Capabilities Structure
|
|
which allows the platform to communicate what features it supports related to
|
|
NVDIMM data persistence. Users can provide a persistence value to a guest via
|
|
the optional "nvdimm-persistence" machine command line option:
|
|
|
|
-machine pc,accel=kvm,nvdimm,nvdimm-persistence=cpu
|
|
|
|
There are currently two valid values for this option:
|
|
|
|
"mem-ctrl" - The platform supports flushing dirty data from the memory
|
|
controller to the NVDIMMs in the event of power loss.
|
|
|
|
"cpu" - The platform supports flushing dirty data from the CPU cache to
|
|
the NVDIMMs in the event of power loss. This implies that the
|
|
platform also supports flushing dirty data through the memory
|
|
controller on power loss.
|
|
|
|
If the vNVDIMM backend is in host persistent memory that can be accessed in
|
|
SNIA NVM Programming Model [1] (e.g., Intel NVDIMM), it's suggested to set
|
|
the 'pmem' option of memory-backend-file to 'on'. When 'pmem' is 'on' and QEMU
|
|
is built with libpmem [2] support (configured with --enable-libpmem), QEMU
|
|
will take necessary operations to guarantee the persistence of its own writes
|
|
to the vNVDIMM backend(e.g., in vNVDIMM label emulation and live migration).
|
|
If 'pmem' is 'on' while there is no libpmem support, qemu will exit and report
|
|
a "lack of libpmem support" message to ensure the persistence is available.
|
|
For example, if we want to ensure the persistence for some backend file,
|
|
use the QEMU command line:
|
|
|
|
-object memory-backend-file,id=nv_mem,mem-path=/XXX/yyy,size=4G,pmem=on
|
|
|
|
References
|
|
----------
|
|
|
|
[1] NVM Programming Model (NPM)
|
|
Version 1.2
|
|
https://www.snia.org/sites/default/files/technical_work/final/NVMProgrammingModel_v1.2.pdf
|
|
[2] Persistent Memory Development Kit (PMDK), formerly known as NVML project, home page:
|
|
http://pmem.io/pmdk/
|
|
[3] ndctl-create-namespace - provision or reconfigure a namespace
|
|
http://pmem.io/ndctl/ndctl-create-namespace.html
|