1
0
mirror of https://gitlab.com/qemu-project/qemu synced 2024-07-08 20:17:27 +00:00

riscv: Fix SiFive E CLINT clock frequency

If you check the manual of SiFive E310 (https://cdn.sparkfun.com/assets/7/f/0/2/7/fe310-g002-manual-v19p05.pdf),
you can see in Figure 1 that the CLINT is connected to the real time clock, which also feeds the AON peripheral (they share the same clock).
In page 43, the docs also say that the timer registers of the CLINT count ticks from the rtcclk.

I am currently playing with bare metal applications both in QEMU and a physical SiFive E310 board and
I confirm that the CLINT clock in the physical board runs at 32.768 kHz.
In QEMU, the same app produces a completely different outcome, as sometimes a new CLINT interrupt is triggered before finishing other tasks.

Resolves: https://gitlab.com/qemu-project/qemu/-/issues/1978

Signed-off-by: Rom\ufffd\ufffdn C\ufffd\ufffdrdenas <rcardenas.rod@gmail.com>
Reviewed-by: Alistair Francis <alistair.francis@wdc.com>
Reviewed-by: Daniel Henrique Barboza <dbarboza@ventanamicro.com>
Message-ID: <20231117082840.55705-1-rcardenas.rod@gmail.com>
Signed-off-by: Alistair Francis <alistair.francis@wdc.com>
This commit is contained in:
Román Cárdenas 2023-11-17 09:28:42 +01:00 committed by Alistair Francis
parent 9bbf03275e
commit a7472560ca

View File

@ -225,7 +225,7 @@ static void sifive_e_soc_realize(DeviceState *dev, Error **errp)
RISCV_ACLINT_SWI_SIZE,
RISCV_ACLINT_DEFAULT_MTIMER_SIZE, 0, ms->smp.cpus,
RISCV_ACLINT_DEFAULT_MTIMECMP, RISCV_ACLINT_DEFAULT_MTIME,
RISCV_ACLINT_DEFAULT_TIMEBASE_FREQ, false);
SIFIVE_E_LFCLK_DEFAULT_FREQ, false);
sifive_e_prci_create(memmap[SIFIVE_E_DEV_PRCI].base);
/* AON */