mirror of
https://github.com/torvalds/linux
synced 2024-09-19 18:46:35 +00:00
f63baced38
IPQ8074 and IPQ6018 dont support negative trip temperatures and support up to 204 degrees C as the max trip temperature. So, instead of always setting the -40 as min and 120 degrees C as max allow it to be configured as part of the features. Signed-off-by: Robert Marko <robimarko@gmail.com> Reviewed-by: Bjorn Andersson <bjorn.andersson@linaro.org> Link: https://lore.kernel.org/r/20220818220245.338396-3-robimarko@gmail.com Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> |
||
---|---|---|
.. | ||
Kconfig | ||
lmh.c | ||
Makefile | ||
qcom-spmi-adc-tm5.c | ||
qcom-spmi-temp-alarm.c | ||
tsens-8960.c | ||
tsens-v0_1.c | ||
tsens-v1.c | ||
tsens-v2.c | ||
tsens.c | ||
tsens.h |