Krzysztof Kozlowski 7fbf6b731b power: supply: max17042: Do not enforce (incorrect) interrupt trigger type
Interrupt line can be configured on different hardware in different way,
even inverted.  Therefore driver should not enforce specific trigger
type - edge falling - but instead rely on Devicetree to configure it.

The Maxim 17047/77693 datasheets describe the interrupt line as active
low with a requirement of acknowledge from the CPU therefore the edge
falling is not correct.

The interrupt line is shared between PMIC and RTC driver, so using level
sensitive interrupt is here especially important to avoid races.  With
an edge configuration in case if first PMIC signals interrupt followed
shortly after by the RTC, the interrupt might not be yet cleared/acked
thus the second one would not be noticed.