linux/drivers/infiniband
Roland Dreier 09f60f8f54 IPoIB/cm: Fix receive QP cleanup
Commit 1b524963 ("IPoIB/cm: Use common CQ for CM send completions")
changed how the high-order bits of work request IDs were used, which
had the effect that IPOIB_CM_RX_DRAIN_WRID was no longer handled as a
connected mode receive completion.  This leads to the messages

    ib1: cm send completion event with wrid 1073741823 (> 64)
    ib1: RX drain timing out

when an interface with connected mode QPs is brought down.  Fix this
by making sure that both IPOIB_OP_CM and IPOIB_OP_RECV are set in
IPOIB_CM_RX_DRAIN_WRID.

Signed-off-by: Roland Dreier <rolandd@cisco.com>
2007-10-26 13:44:25 -07:00
..
core Merge branch 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/roland/infiniband 2007-10-23 09:56:11 -07:00
hw Merge branch 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/roland/infiniband 2007-10-23 09:56:11 -07:00
ulp IPoIB/cm: Fix receive QP cleanup 2007-10-26 13:44:25 -07:00
Kconfig IB: Use menuconfig for InfiniBand menu 2007-07-09 20:12:26 -07:00
Makefile IB/mlx4: Add a driver Mellanox ConnectX InfiniBand adapters 2007-05-08 18:00:38 -07:00