Commit graph

23 commits

Author SHA1 Message Date
Guvenc Gulce 8a44653689 net/smc: use memcpy instead of snprintf to avoid out of bounds read
Using snprintf() to convert not null-terminated strings to null
terminated strings may cause out of bounds read in the source string.
Therefore use memcpy() and terminate the target string with a null
afterwards.

Fixes: a3db10efcc ("net/smc: Add support for obtaining SMCR device list")
Signed-off-by: Guvenc Gulce <guvenc@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2021-01-12 20:22:01 -08:00
Guvenc Gulce aaf95523d5 net/smc: Add support for obtaining SMCD device list
Deliver SMCD device information via netlink based
diagnostic interface.

Signed-off-by: Guvenc Gulce <guvenc@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2020-12-01 17:56:13 -08:00
Guvenc Gulce 49407ae2bc net/smc: Refactor smc ism v2 capability handling
Encapsulate the smc ism v2 capability boolean value
in a function for better information hiding.

Signed-off-by: Guvenc Gulce <guvenc@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
2020-12-01 17:56:12 -08:00
Karsten Graul fd6ebb6fb2 net/smc: use an array to check fields in system EID
The check for old hardware versions that did not have SMCDv2 support was
using suspicious pointer magic. Address the fields using an array.

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-10-03 17:04:48 -07:00
Ursula Braun d70bf4f7a9 net/smc: determine proposed ISM devices
SMCD Version 2 allows to propose up to 8 additional ISM devices
offered to the peer as candidates for SMCD communication.
This patch covers determination of the ISM devices to be proposed.
ISM devices without PNETID are preferred, since ISM devices with
PNETID are a V1 leftover and will disappear over the time.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-28 15:19:03 -07:00
Ursula Braun 8caaccf521 net/smc: introduce CHID callback for ISM devices
With SMCD version 2 the CHIDs of ISM devices are needed for the
CLC handshake.
This patch provides the new callback to retrieve the CHID of an
ISM device.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-28 15:19:03 -07:00
Ursula Braun 201091ebb2 net/smc: introduce System Enterprise ID (SEID)
SMCD version 2 defines a System Enterprise ID (short SEID).
This patch contains the SEID creation and adds the callback to
retrieve the created SEID.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-09-28 15:19:02 -07:00
Ursula Braun 82087c0330 net/smc: switch smcd_dev_list spinlock to mutex
The similar smc_ib_devices spinlock has been converted to a mutex.
Protecting the smcd_dev_list by a mutex is possible as well. This
patch converts the smcd_dev_list spinlock to a mutex.

Fixes: c6ba7c9ba4 ("net/smc: add base infrastructure for SMC-D and ISM")
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-07-08 12:35:15 -07:00
Karsten Graul 0a99be434d net/smc: log important pnetid and state change events
Print to system log when SMC links are available or go down, link group
state changes or pnetids are applied to and removed from devices.
The log entries are triggered by either user configuration actions or
adapter activation/deactivation events and are not expected to happen
often. The entries help SMC users to keep track of the SMC link group
status and to detect when actions are needed (like to add replacements
for failed adapters).

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-05-05 12:56:52 -07:00
Karsten Graul fdff704dc6 net/smc: rework pnet table to support SMC-R failover
The pnet table stored pnet ids in the smc device structures. When a
device is going down its smc device structure is freed, and when the
device is brought online again it no longer has a pnet id set.
Rework the pnet table implementation to store the device name with their
assigned pnet id and apply the pnet id to devices when they are
registered.

Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2020-04-29 12:26:32 -07:00
Ursula Braun 5edd6b9cb8 net/smc: introduce bookkeeping of SMCD link groups
If the ism module is unloaded return control from exit routine only,
if all link groups are freed.
If an IB device is thrown away return control from device removal only,
if all link groups belonging to this device are freed.
A counters for the total number of SMCD link groups per ISM device is
introduced. ism module unloading continues only if the total number of
SMCD link groups for all ISM devices is zero. ISM device
removal continues only it the total number of SMCD link groups per ISM
device has decreased to zero.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-15 12:28:28 -08:00
Ursula Braun 5421ec281d net/smc: abnormal termination of SMCD link groups
A final cleanup due to SMCD device removal means immediate freeing
of all link groups belonging to this device in interrupt context.

This patch introduces a separate SMCD link group termination routine,
which terminates all link groups of an SMCD device.

This new routine smcd_terminate_all ()is reused if the smc module is
unloaded.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-15 12:28:28 -08:00
Ursula Braun 42bfba9eaa net/smc: immediate termination for SMCD link groups
SMCD link group termination is called when peer signals its shutdown
of its corresponding link group. For regular shutdowns no connections
exist anymore. For abnormal shutdowns connections must be killed and
their DMBs must be unregistered immediately. That means the SMCR method
to delay the link group freeing several seconds does not fit.

This patch adds immediate termination of a link group and its SMCD
connections and makes sure all SMCD link group related cleanup steps
are finished.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-15 12:28:28 -08:00
Ursula Braun 50c6b20eff net/smc: fix final cleanup sequence for SMCD devices
If peer announces shutdown, use the link group terminate worker for
local cleanup of link groups and connections to terminate link group
in proper context.

Make sure link groups are cleaned up first before destroying the
event queue of the SMCD device, because link group cleanup may
raise events.

Send signal shutdown only if peer has not done it already.

Send socket abort or close only, if peer has not already announced
shutdown.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-11-15 12:28:28 -08:00
Ursula Braun c3d9494e68 net/smc: no new connections on disappearing devices
Add a "going_away" indication to ISM devices and IB ports and
avoid creation of new connections on such disappearing devices.

And do not handle ISM events if ISM device is disappearing.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
2019-10-09 19:45:44 -07:00
Ursula Braun a0a62ee15a net/smc: separate locks for SMCD and SMCR link group lists
This patch introduces separate locks for the split SMCD and SMCR
link group lists.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
2019-10-09 19:45:44 -07:00
Ursula Braun a2351c5d86 net/smc: separate SMCD and SMCR link group lists
Currently SMCD and SMCR link groups are maintained in one list.
To facilitate abnormal termination handling they are split into
a separate list for SMCR link groups and separate lists for SMCD
link groups per SMCD device.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
2019-10-09 19:45:44 -07:00
Kangjie Lu e183d4e414 net/smc: fix a NULL pointer dereference
In case alloc_ordered_workqueue fails, the fix returns NULL
to avoid NULL pointer dereference.

Signed-off-by: Kangjie Lu <kjlu@umn.edu>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2019-04-11 11:04:08 -07:00
Hans Wippel 0512f69e38 net/smc: add SMC-D shutdown signal
When a SMC-D link group is freed, a shutdown signal should be sent to
the peer to indicate that the link group is invalid. This patch adds the
shutdown signal to the SMC code.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-11-21 16:14:56 -08:00
Ursula Braun 0d86caff06 net/smc: send response to test link signal
With SMC-D z/OS sends a test link signal every 10 seconds. Linux is
supposed to answer, otherwise the SMC-D connection breaks.

Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-08-10 14:38:43 -07:00
Hans Wippel be244f28d2 net/smc: add SMC-D support in data transfer
The data transfer and CDC message headers differ in SMC-R and SMC-D.
This patch adds support for the SMC-D data transfer to the existing SMC
code. It consists of the following:

* SMC-D CDC support
* SMC-D tx support
* SMC-D rx support

The CDC header is stored at the beginning of the receive buffer. Thus, a
rx_offset variable is added for the CDC header offset within the buffer
(0 for SMC-R).

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Suggested-by: Thomas Richter <tmricht@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30 20:42:26 +09:00
Hans Wippel 1619f77058 net/smc: add pnetid support for SMC-D and ISM
SMC-D relies on PNETIDs to find usable SMC-D/ISM devices for a SMC
connection. This patch adds SMC-D/ISM support to the current PNETID
implementation.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Suggested-by: Thomas Richter <tmricht@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30 20:42:25 +09:00
Hans Wippel c6ba7c9ba4 net/smc: add base infrastructure for SMC-D and ISM
SMC supports two variants: SMC-R and SMC-D. For data transport, SMC-R
uses RDMA devices, SMC-D uses so-called Internal Shared Memory (ISM)
devices. An ISM device only allows shared memory communication between
SMC instances on the same machine. For example, this allows virtual
machines on the same host to communicate via SMC without RDMA devices.

This patch adds the base infrastructure for SMC-D and ISM devices to
the existing SMC code. It contains the following:

* ISM driver interface:
  This interface allows an ISM driver to register ISM devices in SMC. In
  the process, the driver provides a set of device ops for each device.
  SMC uses these ops to execute SMC specific operations on or transfer
  data over the device.

* Core SMC-D link group, connection, and buffer support:
  Link groups, SMC connections and SMC buffers (in smc_core) are
  extended to support SMC-D.

* SMC type checks:
  Some type checks are added to prevent using SMC-R specific code for
  SMC-D and vice versa.

To actually use SMC-D, additional changes to pnetid, CLC, CDC, etc. are
required. These are added in follow-up patches.

Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Suggested-by: Thomas Richter <tmricht@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2018-06-30 20:42:25 +09:00