From 9dd6b32e76ff714308964cd9ec91466a343dcb8b Mon Sep 17 00:00:00 2001 From: Thomas Haemmerle Date: Mon, 15 Apr 2024 12:50:27 +0200 Subject: [PATCH] iio: pressure: dps310: support negative temperature values The current implementation interprets negative values returned from `dps310_calculate_temp` as error codes. This has a side effect that when negative temperature values are calculated, they are interpreted as error. Fix this by using the return value only for error handling and passing a pointer for the value. Fixes: ba6ec48e76bc ("iio: Add driver for Infineon DPS310") Signed-off-by: Thomas Haemmerle Link: https://lore.kernel.org/r/20240415105030.1161770-2-thomas.haemmerle@leica-geosystems.com Signed-off-by: Jonathan Cameron --- drivers/iio/pressure/dps310.c | 11 ++++++----- 1 file changed, 6 insertions(+), 5 deletions(-) diff --git a/drivers/iio/pressure/dps310.c b/drivers/iio/pressure/dps310.c index 1ff091b2f764..d0a516d56da4 100644 --- a/drivers/iio/pressure/dps310.c +++ b/drivers/iio/pressure/dps310.c @@ -730,7 +730,7 @@ static int dps310_read_pressure(struct dps310_data *data, int *val, int *val2, } } -static int dps310_calculate_temp(struct dps310_data *data) +static int dps310_calculate_temp(struct dps310_data *data, int *val) { s64 c0; s64 t; @@ -746,7 +746,9 @@ static int dps310_calculate_temp(struct dps310_data *data) t = c0 + ((s64)data->temp_raw * (s64)data->c1); /* Convert to milliCelsius and scale the temperature */ - return (int)div_s64(t * 1000LL, kt); + *val = (int)div_s64(t * 1000LL, kt); + + return 0; } static int dps310_read_temp(struct dps310_data *data, int *val, int *val2, @@ -768,11 +770,10 @@ static int dps310_read_temp(struct dps310_data *data, int *val, int *val2, if (rc) return rc; - rc = dps310_calculate_temp(data); - if (rc < 0) + rc = dps310_calculate_temp(data, val); + if (rc) return rc; - *val = rc; return IIO_VAL_INT; case IIO_CHAN_INFO_OVERSAMPLING_RATIO: