ARM: bcm2835: fix clock node aliasing in device tree

Both clock nodes in the current device tree are named "clock" and hence
end up being the same node. Rename the nodes to different names to avoid
this. In fact, fixed-clock uses the node name as the clock name, so name
the nodes after the clock they represent. Move the clocks into a
"clocks" sub-node to group them and avoid any possible naming conflicts
with other nodes also named after the device type.

Signed-off-by: Stephen Warren <swarren@wwwdotorg.org>
This commit is contained in:
Stephen Warren 2013-01-14 21:07:20 -07:00
parent 232fed4825
commit 9692c191ff

View file

@ -89,15 +89,23 @@ sdhci: sdhci {
};
};
clk_i2c: clock {
compatible = "fixed-clock";
#clock-cells = <0>;
clock-frequency = <150000000>;
};
clocks {
compatible = "simple-bus";
#address-cells = <1>;
#size-cells = <0>;
clk_mmc: clock {
compatible = "fixed-clock";
#clock-cells = <0>;
clock-frequency = <100000000>;
clk_mmc: mmc {
compatible = "fixed-clock";
reg = <0>;
#clock-cells = <0>;
clock-frequency = <100000000>;
};
clk_i2c: i2c {
compatible = "fixed-clock";
reg = <1>;
#clock-cells = <0>;
clock-frequency = <150000000>;
};
};
};