[PATCH] libata: set PIO-0 after successful EH reset

Set ata_device->pio_mode to XFER_PIO_0 after a successful reset.  This
is to keep EH resets consistent with probe resets as updated by the
commit b6079ca409.  Note that, with
soon-to-follow hotplug update, EH resets will include probe resets.

Signed-off-by: Tejun Heo <htejun@gmail.com>
This commit is contained in:
Tejun Heo 2006-05-31 18:27:23 +09:00
parent ef2824073f
commit 20952b6990

View file

@ -1287,7 +1287,7 @@ static int ata_eh_reset(struct ata_port *ap, ata_reset_fn_t softreset,
unsigned int classes[ATA_MAX_DEVICES];
int tries = ATA_EH_RESET_TRIES;
ata_reset_fn_t reset;
int rc;
int i, rc;
if (softreset && (!hardreset || (!sata_set_spd_needed(ap) &&
!(ehc->i.action & ATA_EH_HARDRESET))))
@ -1319,6 +1319,12 @@ static int ata_eh_reset(struct ata_port *ap, ata_reset_fn_t softreset,
}
if (rc == 0) {
/* After the reset, the device state is PIO 0 and the
* controller state is undefined. Record the mode.
*/
for (i = 0; i < ATA_MAX_DEVICES; i++)
ap->device[i].pio_mode = XFER_PIO_0;
if (postreset)
postreset(ap, classes);