Commit graph

1463 commits

Author SHA1 Message Date
Peter Wemm 6ceeb6902a utmp.ut_time and lastlog.ll_time are explicitly int32_t rather than
time_t.  Deal with the possibility that time_t != int32_t.  This boils
down to this sort of thing:
 -   time(&ut.ut_time);
 +   ut.ut_time = time(NULL);
and similar for ctime(3) etc.  I've kept it minimal for the stuff
that may need to be portable (or 3rd party code), but used Matt's time32
stuff for cases where that isn't as much of a concern.

Approved by: re (jhb)
2002-11-15 22:42:00 +00:00
Brian Somers 3c34956a21 If the peer gives us 0.0.0.0 as his IP number, NAK it rather than accepting
it as being in range.

  set ifaddr 1.2.3.4/0 5.6.7.8/0

no longer allows 0.0.0.0 as a valid IP.

Reported/tested by:	Bohdan Horst <nexus@hoth.amu.edu.pl>
MFC after:		3 days
2002-09-23 22:40:43 +00:00
Brian Somers 31c759c0ef Unbreak -DNOINET6
Submitted by:	Andre Albsmeier <andre.albsmeier@mchp.siemens.de>
MFC after:	1 day
2002-09-02 13:34:27 +00:00
Maxim Sobolev 88202a1f33 Correctly handle ifr.ifr_flags/ifr.ifr_flagshigh like ifconfig(8) does.
MFC after:	1 day
2002-08-29 12:52:28 +00:00
Brian Somers a3c48b40e9 - made ppp compliant to RFC 2472 (based on a patch from another
contributor)
- support ipv6cpretry and ipv6cpretries, which are IPv6 versions
  of ipcpretry and ipcpretries.
- improve handling of IPv6 link-local addresses

Submitted by: JINMEI Tatuya <jinmei@isl.rdc.toshiba.co.jp>
2002-08-29 02:44:58 +00:00
Brian Somers 6eafd35305 Include the correct file (stdarg.h) and use va_list rather than _BSD_VA_LIST_
Suggested by: mike
2002-08-27 20:11:58 +00:00
Brian Somers 90f28f9c3b Use _BSD_VA_LIST_ rather than __va_list if it's defined 2002-08-27 04:37:04 +00:00
Brian Somers abc1373d37 Correct the FAQ url
Submitted by: Olivier Tharan <olive@oban.frmug.org>
2002-08-26 20:48:07 +00:00
Philippe Charnier f0067240a1 Replace various spelling with FALLTHROUGH which is lint()able 2002-08-25 13:30:43 +00:00
Mike Barcroft abbd890233 o Merge <machine/ansi.h> and <machine/types.h> into a new header
called <machine/_types.h>.
o <machine/ansi.h> will continue to live so it can define MD clock
  macros, which are only MD because of gratuitous differences between
  architectures.
o Change all headers to make use of this.  This mainly involves
  changing:
    #ifdef _BSD_FOO_T_
    typedef	_BSD_FOO_T_	foo_t;
    #undef _BSD_FOO_T_
    #endif
  to:
    #ifndef _FOO_T_DECLARED
    typedef	__foo_t	foo_t;
    #define	_FOO_T_DECLARED
    #endif

Concept by:	bde
Reviewed by:	jake, obrien
2002-08-21 16:20:02 +00:00
Ruslan Ermilov a654c53e16 mdoc(7) police: Removed redundant .Ns calls. 2002-08-13 16:07:28 +00:00
Marc Fonvieille 9a091256a9 Correct URL to the FAQ
MFC after:	1 week
2002-07-31 10:05:00 +00:00
Marc Fonvieille 1061be04b3 Correct links to Handbook's pages, old URLs does not work anymore.
MFC after:	1 week
2002-07-30 21:04:26 +00:00
Brian Somers 541e4966fc Do a case insensitive comparison when comparing the ms-chap response
string.
2002-07-30 08:09:26 +00:00
Brian Somers f4359ccbbc Remove unused calls to inet_addr() 2002-07-18 18:50:05 +00:00
Brian Somers 4dc4e1ee89 Back out the previous revision
Objected to by: Andre Oppermann <oppermann@pipeline.ch>

After Andre's objection, I've re-examined rfc 2759 and noted that it
says that the domain name shouldn't be used when generating the
NT-Response field.  So it looks like the bug is in freeradius rather
than in ppp.
2002-07-04 23:33:35 +00:00
Brian Somers 27dc75f10c If we've given a domain name prefix as the authentication name, strip
it off before passing it on to the RADIUS server for authentication.
2002-07-03 20:51:13 +00:00
Brian Somers 3285bb3c97 Don't trust the MPPE key lengths passed back from the RADIUS server.
Instead, use the correct values based on the number of bits actually
negotiated.

Spotted by: Sergey Korolew <ds@rt.balakovo.ru>
2002-07-02 00:47:24 +00:00
Brian Somers e0efa79664 Remove some misleading/wrong diagnostics 2002-07-02 00:12:24 +00:00
Brian Somers dfc1b4ac01 Show the port number (tty slot, pppoe session id etc) under
``show physical''.
2002-06-30 01:46:22 +00:00
Brian Somers 6ca7707b44 When a netgraph message is read, look for another before returning.
This removes a bad latency problem during initial setup where we
end up waiting for too long before reading the connected message
and time the connection out.

Problem figured out by:	Andre Albsmeier <andre@albsmeier.net>
2002-06-29 18:49:08 +00:00
Brian Somers 23ddebe20f Don't use SignalBundle if it's not set
Submitted by: Federico G. Schwindt <fgsch@olimpo.com.br>
2002-06-28 09:33:25 +00:00
Brian Somers 579abfd895 Complain about (and fix) misformatted RADIUS attributes rather than silently
fixing them.
2002-06-28 09:18:15 +00:00
Brian Somers 2f11f09fee When a RADIUS server is being used, don't use MPPE unless the RADIUS
server says it's ok.
2002-06-28 08:46:21 +00:00
Brian Somers 99cfc2e2b2 Add a hack to handle RADIUS responses from peers that forget that
there's an ``Ident'' field in the MS-CHAP2-Response and
MS-CHAP-Error attributes.

The RADIATOR server seems to be guilty of this.
2002-06-23 23:38:06 +00:00
Brian Somers dbc46ca401 Don't expect NUL terminated data in all netgraph messages received.
Only display message hook values we understand.
2002-06-22 21:01:47 +00:00
Brian Somers 250be50b72 Compensate for dodgy Win98/WinME MSCHAPv2 responses later in the code
path... after we've talked to any RADIUS servers involved, so that we
haven't touched the data before it gets to the server.

Make it clearer in the code that this compensation is done by setting
a flag to a value of zero, a flag which rfc2759 says *MUST* be zero.

While we're here, don't bother passing the peer challenge into
radius_Authenticate().  It's already part of the key we're passing in
(this becomes obvious now that I've structured that data...).

This ``fix'' doesn't help to authenticate Win98/WinME users in my test
environment as ports/net/freeradius seems to ignore the flag
completely anyway, but it may help with other RADIUS servers.
2002-06-17 01:12:38 +00:00
Brian Somers 3627fe880c A better prinflike fix... 2002-06-15 08:03:59 +00:00
Brian Somers 10be78d3ae Remove whitespace at the end of lines. 2002-06-15 08:03:30 +00:00
Brian Somers 3db951841c Fix a printflike format error 2002-06-15 01:36:36 +00:00
Brian Somers 61fe3f63bc Remove a forgotten diagnostic 2002-06-15 01:35:03 +00:00
Brian Somers 635ad5f021 If a RAD_FILTER_ID is supplied by the RADIUS server, treat it as an
additional label from ppp.linkup & ppp.linkdown to load.

Suggested and mostly submitted by: andrew pavlov <and@kremenchug.net>
2002-06-12 23:45:15 +00:00
Brian Somers aea6acb6da Bump the version number to reflect the recent RADIUS commits 2002-06-12 23:00:12 +00:00
Brian Somers a95b23a6b2 Don't forget to process the Ident field on the front of
RAD_MICROSOFT_MS_CHAP_ERROR and RAD_MICROSOFT_MS_CHAP2_SUCCESS
messages, and remove the hack in chap.c to ignore that ident field
on the client side.

This anomoly was hacked around during development, and I forgot to
go back and fix it properly.

Spotted by: Sergey Korolew <ds@rt.balakovo.ru>
2002-06-12 21:36:07 +00:00
Brian Somers 8fb5ef5ae2 Understand the following Microsoft Vendor Specific RADIUS attributes:
RAD_MICROSOFT_MS_MPPE_ENCRYPTION_POLICY
  RAD_MICROSOFT_MS_MPPE_ENCRYPTION_TYPES
  RAD_MICROSOFT_MS_MPPE_RECV_KEY
  RAD_MICROSOFT_MS_MPPE_SEND_KEY

These attributes may be supplied by a RADIUS server when MSCHAPv2 is
used to authenticate.

It *should* now be possible to build ppp with -DNODES and still support
CHAP/MSCHAP/MSCHAPv2/MPPE via a RADIUS server, but the code isn't yet
smart enough to do that (building with -DNODES just looses these
facilities).

Sponsored by: Monzoon
2002-06-12 00:33:17 +00:00
Brian Somers 12b5aaba39 Cast pid_t to long for printf()ing
Obtained from:	OpenBSD
2002-06-06 01:39:46 +00:00
Brian Somers 7b5e6f62fb Add a missing ``a''. 2002-06-03 21:36:20 +00:00
Brian Somers aadbb4eab1 Don't send a RAD_NAS_IP_ADDRESS attribute as RAD_NAS_IDENTIFIER is
sufficient.

In fact, using both breaks the radiator RADIUS daemon when used with
a db as it maps both attributes to the same field value and then
fails the insert.

I decided to remove RAD_NAS_IP_ADDRESS on the basis that rfc2138 says:

      An Access-Request MUST contain a User-Name attribute.  It SHOULD
      contain either a NAS-IP-Address attribute or NAS-Identifier
      attribute (or both, although that is not recommended).  It MUST

despite the fact that this not recommended bit was removed from the
updated rfc.
2002-06-02 14:27:02 +00:00
Brian Somers 42df3c252e Coerce pid_t to long rather than int for better portability.
Suggested by: Theo de Raadt <deraadt@openbsd.org>
2002-05-27 23:19:53 +00:00
Brian Somers d4ff125fc1 Increase the maximum FSM option length to 50 2002-05-22 21:17:13 +00:00
Brian Somers b08bf2de64 Add some missing #includes that weren't required due to namespace polution
in our headers.

Submitted by: bde
2002-05-22 21:08:58 +00:00
Brian Somers 3eaa768da0 Mention our support of the authentication side of rfc2548 2002-05-21 10:54:07 +00:00
Brian Somers d5caaf02c1 Document RAD_MICROSOFT_MS_CHAP2_SUCCESS. 2002-05-18 23:58:15 +00:00
Brian Somers 5bc74cd68f Put back <string.h> 2002-05-17 00:44:54 +00:00
Brian Somers 52c555907f Add some OpenBSD includes 2002-05-16 14:47:19 +00:00
Brian Somers 6573c25286 Fix a mis-placed #else/#endif 2002-05-16 14:28:32 +00:00
Brian Somers a16061b236 Handle MS-CHAPv2 authentication correctly via the RADIUS server (if it's
configured).
Handle internal failures in radius_Authenticate() correctly.
Bump the ppp version number.

This doesn't yet work with MPPE.  More will follow.

Sponsored by: Mozoon
2002-05-16 13:34:20 +00:00
Brian Somers 6f4cd65600 Fix an include for NetBSD 2002-05-14 17:50:25 +00:00
Brian Somers d76a00091c Avoid a rather bizarre warning from gcc 3.1:
/usr/src/usr.sbin/ppp/cbcp.c:566:61: warning: trigraph ??! ignored
2002-05-14 13:32:30 +00:00
Brian Somers de59e178aa o Clean up some #includes
o Bump version number to 3.0.4
o When talking to a RADIUS server, provide a NAS-Port-Type.

  When the NAS-Port-Type is Ethernet, provide a NAS-Port value equal
  to the SESSIONID from the environment in direct mode or the
  NGM_PPPOE_SESSIONID message in other modes.  If no SESSIONID is found,
  default to the interface index in client mode or zero in server mode.

  When the NAS-Port-Type is ISDN, set the NAS-Port to the minor number
  of the physical device (ie, the N in /dev/i4brbchN).

  This makes it easier for the RADIUS server to identify the client
  WRT accounting data etc.

Prompted by:	lsz8425 <lsz8425@mail.cd.hn.cn>
2002-05-14 12:55:39 +00:00