Commit graph

15 commits

Author SHA1 Message Date
Warner Losh b3e7694832 Remove $FreeBSD$: two-line .h pattern
Remove /^\s*\*\n \*\s+\$FreeBSD\$$\n/
2023-08-16 11:54:16 -06:00
Warner Losh 4d846d260e spdx: The BSD-2-Clause-FreeBSD identifier is obsolete, drop -FreeBSD
The SPDX folks have obsoleted the BSD-2-Clause-FreeBSD identifier. Catch
up to that fact and revert to their recommended match of BSD-2-Clause.

Discussed with:		pfg
MFC After:		3 days
Sponsored by:		Netflix
2023-05-12 10:44:03 -06:00
Oskar Holmund 17b14d8f77 usr.sbin/pwm/pwm add support for flags
The pwm utility cant set the only flag defined (PWM_POLARITY_INVERTED) so this
patch add the option -I (capital letter i) to send it to the drivers.

None of existing PWM driver have implemented support for flags.
But soon:ish I will put up an review of a pwm driver using TI OMAP DMTimer.

Differential Revision: https://reviews.freebsd.org/D29137
MFC after:   2 weeks
2021-03-11 09:57:56 +01:00
Andriy Gapon a4f28d4296 pwm(8): fix potential duty overflow, use unsigneds for period and duty
For a long period value and the duty specified as a percentage,
there could be an overflow.
Using unsigned integers aligns the code with struct pwm_state and allows
to safely use periods up to 4 seconds where supported by drivers.

MFC after:	2 weeks
2020-09-25 07:55:08 +00:00
Andriy Gapon 31b0753da3 pwm(8): do not exit with failure after successfully reading configuration
MFC after:	1 week
2020-09-25 07:54:38 +00:00
Emmanuel Vadot e213223c9b Remove "all rights reserved" from copyright for the file I own.
Some of the files have both me and Jared McNeill and he gave me
permission to remove it from his files too.
2019-12-03 21:00:45 +00:00
Ian Lepore 26f3ca615d Rearrange the argument checking and processing so that enable and disable
can be combined with configuring the period and duty cycle (the same ioctl
sets all 3 values at once, so there's no reason to require the user to run
the program twice to get all 3 things set).
2019-06-18 01:15:00 +00:00
Ian Lepore 780c3de886 Remove everything related to channels from the pwmc public interface, now
that there is a pwmc(4) instance per channel and the channel number is
maintained as a driver ivar rather than being passed in from userland.
2019-06-18 00:11:00 +00:00
Ian Lepore 7d763870e4 Follow changes in the pwmc(4) driver in relation to device filenames.
The driver now names its cdev nodes pwmcX.Y where X is unit number and
Y is the channel within that unit.  Change the default device name from
pwmc0 to pwmc0.0.  The driver now puts cdev files and label aliases in
the /dev/pwm directory, so allow the user to provide unqualified names
with -f and automatically prepend the /dev/pwm part for them.

Update the examples in the manpage to show the new device name format
and location within /dev/pwm.
2019-06-17 16:43:33 +00:00
Ian Lepore 6cdbe2bf20 Make pwm channel numbers unsigned. 2019-06-15 23:02:09 +00:00
Ian Lepore 71fb373934 Move/rename the sys/pwm.h header file to dev/pwm/pwmc.h. The file contains
ioctl definitions and related datatypes that allow userland control of pwm
hardware via the pwmc device.  The new name and location better reflects its
assocation with a single device driver.
2019-06-15 19:46:59 +00:00
Emmanuel Vadot 50a123aad8 pwm(8): Add percentage value support for duty cycle 2018-12-14 18:38:10 +00:00
Emmanuel Vadot 6a9997ed67 pwm: Convert period and duty to unsigned int
We don't need a 64 bits value to store nanoseconds

Discused with:	ian, jhibbits
2018-12-14 18:37:26 +00:00
Emmanuel Vadot d9848bd254 pwm: Fix some arches by using %ju and casting to uintmax_t
Reported by:	ci.freebsd.org
2018-12-12 21:25:52 +00:00
Emmanuel Vadot 9312900f6d Add a pwm subsystem so we can configure pwm controller from kernel and userland.
The pwm subsystem consist of API for PWM controllers, pwmbus to register them
and a pwm(8) utility to talk to them from userland.

Reviewed by:	oshgobo (capsicum), bcr (manpage), 0mp (manpage)
Differential Revision:	https://reviews.freebsd.org/D17938
2018-12-12 20:56:56 +00:00