ena: Change measurement unit of time since last tx cleanup to ms

This commit:
1. Sets the time since last cleanup to milliseconds.
2. Fixes incorrect indentations.

Approved by: cperciva (mentor)
MFC after: 2 weeks
Sponsored by: Amazon, Inc.
This commit is contained in:
Arthur Kiyanovski 2023-06-14 10:12:16 +00:00 committed by Arthur Kiyanovski
parent f9e1d94710
commit 9272e45c04

View file

@ -3102,13 +3102,13 @@ check_missing_comp_in_tx_queue(struct ena_adapter *adapter,
if (unlikely(time_offset > adapter->missing_tx_timeout)) {
if (tx_buf->print_once) {
time_since_last_cleanup = TICKS_2_USEC(ticks -
time_since_last_cleanup = TICKS_2_MSEC(ticks -
tx_ring->tx_last_cleanup_ticks);
missing_tx_comp_to = sbttoms(
adapter->missing_tx_timeout);
ena_log(pdev, WARN,
"Found a Tx that wasn't completed on time, qid %d, index %d. "
"%d usecs have passed since last cleanup. Missing Tx timeout value %d msecs.\n",
"%d msecs have passed since last cleanup. Missing Tx timeout value %d msecs.\n",
tx_ring->qid, i, time_since_last_cleanup,
missing_tx_comp_to);
}