acpi_battery: avoid divide-by-zero when no devices have capacity info
On laptops with builtin batteries, disconnecting the battery may show up
as a battery without any capacity information. (The theory is that one
is disconnecting the cells but the electronics identifying the battery
are still connected.) As a result, the loop over all batteries in
acpi_battery_get_battinfo results in total_lfcap == 0.
So, just check that total_lfcap is non-zero to avoid a division by zero
(triggerable by sysctl hw.acpi.battery).
Reported by: Stefano Marinelli
Tested by: Stefano Marinelli
Reviewed by: emaste
Differential Revision: https://reviews.freebsd.org/D44818
(cherry picked from commit 2e850b832f
)
This commit is contained in:
parent
7a2c2599a7
commit
788987e034
|
@ -266,7 +266,14 @@ acpi_battery_get_battinfo(device_t dev, struct acpi_battinfo *battinfo)
|
|||
*/
|
||||
if (valid_units > 0) {
|
||||
if (dev == NULL) {
|
||||
battinfo->cap = (total_cap * 100) / total_lfcap;
|
||||
/*
|
||||
* Avoid division by zero if none of the batteries had valid
|
||||
* capacity info.
|
||||
*/
|
||||
if (total_lfcap > 0)
|
||||
battinfo->cap = (total_cap * 100) / total_lfcap;
|
||||
else
|
||||
battinfo->cap = 0;
|
||||
battinfo->min = total_min;
|
||||
battinfo->state = batt_stat;
|
||||