Boy, was *this* ever bollixed!
1. Copyright files looked for in the wrong place 2. cmp was looking in wrong place for test data. 3. Driver for test not linked static, thus dynamic resolution of library not working. 4. Man page installation not consistent with source. Reviewed by: Submitted by: jkh
This commit is contained in:
parent
eaf83dc038
commit
7105368244
Notes:
svn2git
2020-12-20 02:59:44 +00:00
svn path=/head/; revision=1964
1 changed files with 17 additions and 17 deletions
|
@ -2,14 +2,14 @@
|
|||
|
||||
LIB= md
|
||||
SRCS= md2c.c md4c.c md5c.c md2hl.c md4hl.c md5hl.c
|
||||
MAN3+= md2.3 md4.3 md5.3
|
||||
MLINKS+=md2.3 MD2Init.3 md2.3 MD2Update.3 md2.3 MD2Final.3
|
||||
MLINKS+=md2.3 MD2End.3 md2.3 MD2File.3 md2.3 MD2Data.3
|
||||
MLINKS+=md4.3 MD4Init.3 md4.3 MD4Update.3 md4.3 MD4Final.3
|
||||
MLINKS+=md4.3 MD4End.3 md4.3 MD4File.3 md4.3 MD4Data.3
|
||||
MLINKS+=md5.3 MD5Init.3 md5.3 MD5Update.3 md5.3 MD5Final.3
|
||||
MLINKS+=md5.3 MD5End.3 md5.3 MD5File.3 md5.3 MD5Data.3
|
||||
CLEANFILES+= md[245]hl.c md[245].ref md[245].3
|
||||
MAN3+= mdX.3
|
||||
MLINKS+=mdX.3 MD2Init.3 mdX.3 MD2Update.3 mdX.3 MD2Final.3
|
||||
MLINKS+=mdX.3 MD2End.3 mdX.3 MD2File.3 mdX.3 MD2Data.3
|
||||
MLINKS+=mdX.3 MD4Init.3 mdX.3 MD4Update.3 mdX.3 MD4Final.3
|
||||
MLINKS+=mdX.3 MD4End.3 mdX.3 MD4File.3 mdX.3 MD4Data.3
|
||||
MLINKS+=mdX.3 MD5Init.3 mdX.3 MD5Update.3 mdX.3 MD5Final.3
|
||||
MLINKS+=mdX.3 MD5End.3 mdX.3 MD5File.3 mdX.3 MD5Data.3
|
||||
CLEANFILES+= md[245]hl.c md[245].ref md[245].3 mddriver
|
||||
CFLAGS+= -I${.CURDIR}
|
||||
|
||||
md2hl.c: mdXhl.c
|
||||
|
@ -23,15 +23,15 @@ md5hl.c: mdXhl.c
|
|||
|
||||
md2.3: mdX.3
|
||||
sed -e 's/mdX/md2/g' -e 's/MDX/MD2/g' $> > $@
|
||||
cat md2.copyright >> $@
|
||||
cat ${.CURDIR}/md2.copyright >> $@
|
||||
|
||||
md4.3: mdX.3
|
||||
sed -e 's/mdX/md4/g' -e 's/MDX/MD4/g' $> > $@
|
||||
cat md4.copyright >> $@
|
||||
cat ${.CURDIR}/md4.copyright >> $@
|
||||
|
||||
md5.3: mdX.3
|
||||
sed -e 's/mdX/md5/g' -e 's/MDX/MD5/g' $> > $@
|
||||
cat md5.copyright >> $@
|
||||
cat ${.CURDIR}/md5.copyright >> $@
|
||||
|
||||
md2.ref:
|
||||
echo 'MD2 test suite:' > $@
|
||||
|
@ -66,14 +66,14 @@ md5.ref:
|
|||
beforeinstall: md2.ref md4.ref md5.ref md2.3 md4.3 md5.3
|
||||
@echo if any of these test fail, the code produces wrong results
|
||||
@echo and should NOT be used.
|
||||
${CC} ${CFLAGS} -DMD=2 -o mddriver ${.CURDIR}/mddriver.c -L. -lmd
|
||||
./mddriver | cmp ${.CURDIR}/md2.ref -
|
||||
${CC} ${CFLAGS} -static -DMD=2 -o mddriver ${.CURDIR}/mddriver.c -L. -lmd
|
||||
./mddriver | cmp md2.ref -
|
||||
@echo MD2 passed test
|
||||
${CC} ${CFLAGS} -DMD=4 -o mddriver ${.CURDIR}/mddriver.c -L. -lmd
|
||||
./mddriver | cmp ${.CURDIR}/md4.ref -
|
||||
${CC} ${CFLAGS} -static -DMD=4 -o mddriver ${.CURDIR}/mddriver.c -L. -lmd
|
||||
./mddriver | cmp md4.ref -
|
||||
@echo MD4 passed test
|
||||
${CC} ${CFLAGS} -DMD=5 -o mddriver ${.CURDIR}/mddriver.c -L. -lmd
|
||||
./mddriver | cmp ${.CURDIR}/md5.ref -
|
||||
${CC} ${CFLAGS} -static -DMD=5 -o mddriver ${.CURDIR}/mddriver.c -L. -lmd
|
||||
./mddriver | cmp md5.ref -
|
||||
@echo MD5 passed test
|
||||
-rm -f mddriver
|
||||
|
||||
|
|