mirror of
https://github.com/freebsd/freebsd-src
synced 2024-07-22 18:56:38 +00:00
Improvements to the shutdown(8) manual.
PR: 158807 Submitted by: arundel MFC after: 1 week
This commit is contained in:
parent
2b6ce80c82
commit
54d3d7c01c
Notes:
svn2git
2020-12-20 02:59:44 +00:00
svn path=/head/; revision=223991
|
@ -28,7 +28,7 @@
|
|||
.\" @(#)shutdown.8 8.2 (Berkeley) 4/27/95
|
||||
.\" $FreeBSD$
|
||||
.\"
|
||||
.Dd December 30, 2010
|
||||
.Dd July 13, 2011
|
||||
.Dt SHUTDOWN 8
|
||||
.Os
|
||||
.Sh NAME
|
||||
|
@ -83,20 +83,20 @@ If one of the
|
|||
.Fl p
|
||||
or
|
||||
.Fl r
|
||||
is specified,
|
||||
options are specified,
|
||||
.Nm
|
||||
will execute
|
||||
.Xr halt 8
|
||||
or
|
||||
.Xr reboot 8
|
||||
instead of sending signal to
|
||||
instead of sending a signal to
|
||||
.Xr init 8 .
|
||||
.It Fl n
|
||||
If the
|
||||
.Fl o
|
||||
is specified, prevent the file system cache from being flushed by passing
|
||||
option is specified, prevent the file system cache from being flushed by passing
|
||||
.Fl n
|
||||
option to
|
||||
to
|
||||
.Xr halt 8
|
||||
or
|
||||
.Xr reboot 8 .
|
||||
|
@ -106,10 +106,10 @@ This option should probably not be used.
|
|||
is the time at which
|
||||
.Nm
|
||||
will bring the system down and
|
||||
may be the word
|
||||
may be the case-insensitive word
|
||||
.Ar now
|
||||
(indicating an immediate shutdown) or
|
||||
specify a future time in one of two formats:
|
||||
a future time in one of two formats:
|
||||
.Ar +number ,
|
||||
or
|
||||
.Ar yymmddhhmm ,
|
||||
|
@ -148,7 +148,7 @@ exits.
|
|||
.Pp
|
||||
At shutdown time a message is written to the system log, containing the
|
||||
time of shutdown, the person who initiated the shutdown and the reason.
|
||||
Corresponding signal is then sent to
|
||||
The corresponding signal is then sent to
|
||||
.Xr init 8
|
||||
to respectively halt, reboot or bring the system down to single-user state
|
||||
(depending on the above options).
|
||||
|
@ -176,16 +176,18 @@ utility will place the system into single user mode at the
|
|||
.Ar time
|
||||
specified.
|
||||
.Pp
|
||||
Calling utility as
|
||||
.Nm poweroff
|
||||
is equivalent of calling:
|
||||
Calling
|
||||
.Dq Nm poweroff
|
||||
is equivalent to running:
|
||||
.Bd -literal -offset indent
|
||||
shutdown -p now
|
||||
.Ed
|
||||
.Sh FILES
|
||||
.Bl -tag -width /var/run/nologin -compact
|
||||
.It Pa /var/run/nologin
|
||||
tells login not to let anyone log in
|
||||
tells
|
||||
.Xr login 1
|
||||
not to let anyone log in
|
||||
.El
|
||||
.Sh COMPATIBILITY
|
||||
The hours and minutes in the second time format may be separated by
|
||||
|
|
Loading…